2. Safety Devices
We adapt 5 safety devices for users to use this wash machine safely.
1) Balancing device (ASSY-Main PCB)
ª
When the laundry is out of balance, to prevent the noises and vibrations, the unbalance
detecting sensor helps the laundry laid even and continue the dehydrating process.
2) Anti-over water supply device
ª
Because water supply value is broken, once water is supplied to the 2/3 level of the door, the
water supplied is drained automatically,
Over -flow error is displayed on the panel
3) Temperature-regulating device(thermistor)
ª
To prevent over-heating over the temperature set up, THERMISTOR senses the temperature of
the machine continuously and helps the wash machine to work at the temperature given by users.
4 Overheating- controlling system
ª
Under the circumstances of THERMISTOR inferiority or abnormal condition, if wash-heater is
overheated, automatically, assy -thermal fuse cuts off the power supply to protect the machine to
keep it safe.
5) Delicate clothing safeguard function(ASSY-Main PCB)
ª
To protect the clothings which is weak to high temperature, the wash machine senses the
temperature inside the washing tub. if the temperature rises over 50
wool washing course and
Delicate washing course display abnormal water temperature on the panel , after draining the
water.
3. Overview of the Washing Machine
 4. Overview of the control panel
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
ª
5. Main function
1) Auto power S/W off function
 
After power on, the auto power S/W off function automatically switches power off for you if you do not press
selection button for 10 minutes
 
After selecting the function, the auto power S/W off function automatically switches power off for you if you do
not press start/pause button for 10 minutes
 
After finishing the last function, the auto power S/W off function automatically switches
power off for you if you do not re-select the course button or manual button
2) Door open function
 
If door is open during the operating, all operating is halted, and door error message will be displayed and error
melody will come out.
 
Door open error can be cleared by closing the door. the operating keeps going on
3) No spin function
 
If no spin function selected, the operating is finished after last rinse
5. Main function
4) Power-out compensation function
 
If power is out on selected process, the process before power out is stored to EEPROM, once power is back
the process before power out continues.
 
When power is back, washing process starts from the process at the point of the power out, rinse/drain process
starts from the initial process.
POWER-OUT COMPENSATION FUNCTION PROCESS
RINSE/DRAIN
START
RINSE/DRAIN
PROCESS
START
WASHING
FINISH
POWER OUT
POWER OUT
SAVE DATA
to EEPROM
SAVE DATA
to EEPROM
POWER BACK
POWER BACK
MICOM RESTORE
MICOM RESTORE
READ DATA
(PROCESS+TIME)
RESTART
PROCESS
5) Water heater Error function
˝
This function starts working, when the heater works abnormally.
(this function begins sensing the heater 1 minutes later, after the heater operating)
˞
The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes (Y=A2-A1)
- For 10 minutes, the variance of temperature(Y) is less than 2
"The display shows 'E5' "
message is displayed on the panel.
˟
The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes (Y=A2-A1)
- For 2 minute the variance of temperature increases more than 7
"The display shows 'E5' "
message is displayed on the panel.
ˠ
At this time heater, Error "course led 8ea on 30
/60
led on" is displayed and all working process off
ˡ
The heater operating continues during heating hours, if washing hour is left over, the residual washing process
keeps going without heating.